Protocols Modbus TCP
Does Nodlyn support Modbus TCP?
Talk to PLCs and industrial gateways over TCP — discover hosts on your LAN, then read/write registers in a visual workflow.
Compatibility answer
Yes — at the protocol level. Nodlyn can discover Modbus TCP endpoints and register them for visual workflows.
Nodlyn can scan a subnet for Modbus TCP listeners (port 502) and help you add them to a workflow.
What Modbus TCP support means in Nodlyn
Modbus TCP is still the default language on many plant floors: PLCs, energy meters, and protocol gateways expose holding and input registers over port 502. Nodlyn treats that as a first-class discovery target — scan a subnet, accept a host, then map registers into thresholds, Influx/SQLite logs, or Slack alerts without writing a poller.
If your PLC only speaks Modbus RTU on RS-485, use a TCP gateway or the Serial connector and keep the same visual workflow pattern. Compatibility here means register read/write in Studio and runtime agents — not a replacement for your PLC program.
This page is a compatibility check (supported or not, how you connect). Step-by-step tutorials live on the blog when linked below — so Google (and readers) get one clear “how-to” URL.
Example automations with Modbus TCP
- PLC register → threshold → Slack/SMS
- Energy meter → InfluxDB/SQLite log
- Gateway poll → runtime agent on edge PC
Quick start for Modbus TCP
- Open Discovery → Industrial & building automation (or Advanced → Modbus).
- Set your LAN subnet (e.g. 192.168.1.0/24) and start a scan.
- Accept a found device, or drop a Modbus TCP node and enter the PLC IP manually.
- Map holding/input registers and connect thresholds, logs, or alerts.
Brands people ask about for Modbus TCP
Curated examples — not an exhaustive SKU database. Same protocol family usually wires the same way. Missing model? Request confirmation on /protocols.
- Schneider Modicon
- ABB
- Wago
- Unitronics
- Generic Modbus gateway
Can Nodlyn auto-discover Modbus TCP devices?
Yes. Nodlyn can scan a subnet for Modbus TCP listeners (port 502) and help you add them to a workflow. You can also add endpoints manually if discovery is empty.
In-depth Modbus TCP guide (blog)
For configuration details, examples, and troubleshooting, use the long-form guide — that URL is the primary “how to” page: Device Discovery: Matter, Zigbee, Z-Wave, CAN Bus & More.
Related protocols
Try Modbus TCP on your LAN
Download the free desktop beta, sign in with your free account, and open Discovery.