Protocols OPC UA

Industrial & building

Does Nodlyn support OPC UA?

Read and write industrial tags from OPC UA servers — common on modern PLCs and SCADA gateways.

Manual endpoint

Compatibility answer

Yes — at the protocol level. Nodlyn ships OPC UA blocks in the connector library; you point them at your host or broker.

Point an OPC UA node at your server endpoint (opc.tcp://…) — no subnet scan required.

What OPC UA support means in Nodlyn

OPC UA is the modern industrial tag layer: secure endpoints, browsable node IDs, and setpoints you can write from a workflow. Nodlyn’s OPC UA blocks connect to servers from TIA Portal, TwinCAT, Kepware, Ignition, and similar stacks — you paste the opc.tcp URL and choose the tag.

There is no subnet “OPC UA scan” like Modbus port 502; compatibility means the connector + auth modes you configure in the Inspector. Once connected, the same Condition / Alert / Database blocks work as with any other protocol.

This page is a compatibility check (supported or not, how you connect). Step-by-step tutorials live on the blog when linked below — so Google (and readers) get one clear “how-to” URL.

Example automations with OPC UA

  • Tag read → condition → maintenance ticket
  • Write setpoint from approved workflow
  • SCADA gateway → dashboard feed

Quick start for OPC UA

  1. Add an OPC UA block from the Devices & Protocols palette.
  2. Enter the server URL and security settings from your PLC/SCADA docs.
  3. Select the tag (node id) to read or write.
  4. Wire the value into conditions, databases, or alerts.

Brands people ask about for OPC UA

Curated examples — not an exhaustive SKU database. Same protocol family usually wires the same way. Missing model? Request confirmation on /protocols.

  • Siemens (OPC UA)
  • Beckhoff
  • Kepware / PTC
  • Ignition (OPC UA)

Do I need discovery for OPC UA?

No. Point an OPC UA node at your server endpoint (opc.tcp://…) — no subnet scan required. Discovery is optional for protocols that use a known URL, broker, or PLC address.

In-depth OPC UA guide (blog)

For configuration details, examples, and troubleshooting, use the long-form guide — that URL is the primary “how to” page: OPC UA on the Shop Floor.

Related protocols

Try OPC UA on your LAN

Download the free desktop beta, sign in with your free account, and open Discovery.

Download Free Beta All protocols